This report is sent to the gateway whenever a node start. It contains requirements for the node (does it need to be assigned a nodeId for exemple).
#bytes# | data type | description |
---|---|---|
1 | unsigned char | Message type |
1 | unsigned char | Major version |
1 | unsigned char | Minor version |
4 | long | signature |
1 | byte | true if new rf node id needed |